Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
04/15/2024 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
WIC 39
chest freezer 6
small cooler 35
Ref 30/03
Chest freezer prep area 6
Warmer 108-106
freezer back room -10

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out Due to 5 priority violations, many repeat violation that have not been corrected, Not using the proper sanitizer ( scent bleach). No date marking in place, foods in warmer not maintaining hot holding temps. Priority Foundation (PF) 0
01 0080-04-09-.02(1)(c) Person in charge - Duties out PIC shall ensure active managerial control of duties/ training as required in the Retail Store Sanitation Regulations .. Priority Foundation (PF) 0
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)2 Handwashing sinks, properly supplied with soap out no soap at hand sink in prep area Priority Foundation (PF) 0
08 0080-04-09-.06(3)(a)3 Handwashing sinks, properly supplied with drying devices out no paper towels at either hand sink Priority Foundation (PF) 1
13 Food separated and protected in 0
13 0080-04-09-.03(3)(b)1(i)(I) Raw animal foods must be kept separate from ready to eat foods at all times out raw eggs stored over RTE bolonga Priority (P) 0
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions out no sanitizer in ware wash area ,, facility had bleach on retail shelf ( scented) Priority (P) 0
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out Pizza @ 106-108, tenders 107 degrees ( all disposed ) Priority (P) 0
21,22 Date & Time for food safety in 0
21,22 21 Date Marking and Disposition in 0
21,22 0080-04-09-.03(5)(a)7 Date Marking; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, ... out no date marking on open bulk pizza sausage , no date marking on open chub bolonga Priority (P) 0
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable out No thermometer observed in small cooler at fountain area Priority Foundation (PF) 1
35,36 Pests & contamination in 0
35,36 36 Contamination prevented during food preparation, storage or display in 0
35,36 0080-04-09-.03(3)(b)1 Preventing packaged and unpackaged food contamination by separation, packaging, and segregation methods out open foods stored open ( burger patties ) not covered or protected Priority (P) 0
35,36 0080-04-09-.03(3)(e) Food shall be stored in a clean location, not exposed to contamination, at least 6 inches above the floor. Food shall not be stored in prohibited areas such as: locker/ch... out Condiments stored directly on floor under warmer Core (C) 0
40,41 Utensils in 0
40,41 40 In use utensils properly stored in 0
40,41 0080-04-09-.03(3)(d)2 In use utensils for food preparation or dispensing shall be stored properly; handle above food, or in running water, and protected. out tongs ar warmer not covered or protected Core (C) 1
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(a)2 Warewashing sink must have 3 compartments and be adequately sized for equipment being washed out ware wash sink leaking not holding water Priority Foundation (PF) 1
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Vent a hood grease build up needs cleaning Core (C) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.06(2)(b)4 Toilet room shall have a self-closing tight fitting door out rest room door not self closing Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 37 63 63
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 4 41 91
Priority (P) 49 5 44 89
Priority Foundation (PF) 39 6 33 84