Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
04/05/2023 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Walk-in cooler 57
Deli Case (not working)
Condiment case (not working)
Chest Freezer (In kitchen area) -2
Undercounter -10
Novelty Case (not working)

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Three compartment sink Bleach

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)2 Handwashing sinks, properly supplied with soap out There was no soap at the hand sink near the restrooms. Priority Foundation (PF) 2
08 0080-04-09-.06(3)(a)3 Handwashing sinks, properly supplied with drying devices out There were no paper towels at any of the handwashing sinks. Priority Foundation (PF) 2
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(6)(a) Food contact surfaces shall be visually clean. out The ice machine had black residue inside. Priority Foundation (PF) 2
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(3)(b)2 Probe thermometer shall be readily accessible to check food temperatures out No thermometer present. Priority Foundation (PF) 0
40,41 Utensils in 0
40,41 40 In use utensils properly stored in 0
40,41 0080-04-09-.03(3)(d)2 In use utensils for food preparation or dispensing shall be stored properly; handle above food, or in running water, and protected. out The ice scoop was uncovered. Core (C) 0
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out There were no test strips for the chlorine. Priority Foundation (PF) 2
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out The vents in the walk-in cooler were unclean. The beverage shelves in the walk-in cooler were unclean and had dust build-up. Core (C) 1
47,48,49 Plumbing in 0
47,48,49 48 Plumbing installed; backflow devices in 0
47,48,49 0080-04-09-.05(2)(b)3 Air gap sufficient between water supply outlet and flood rim level out The ice machine does not have an air gap at the ice machine drain. Priority (P) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. out There was no covered trash can in the women's restroom. Core (C) 0
50 0080-04-09-.06(2)(b)4 Toilet room shall have a self-closing tight fitting door out The restrooms did not have self-closing doors. Core (C) 0
50 0080-04-09-.06(4)(b) Toilet rooms shall be conveniently located and accessible out The door is obstructed. Core (C) 0
51,52 Facilities in 0
51,52 51 Garbage and refuse properly disposed; facilities maintained in 0
51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. out The dumpster lid was open. Core (C) 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(2)(a) Floors, walls and ceilings - Designed, constructed, and installed smooth and easily cleanable out The floor in front of the ice machine tiles were broken and missing. Core (C) 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out The deli case, condiment case, and novelty case are not working. The walk-in cooler (WIC) is not working properly working. The WIC has a temperature of 57 degrees (no milk inside). Core (C) 2
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out The retail shelves were unclean. The floor was unclean and appears to need mopping. Core (C) 0
51,52 0080-04-09-.06(5)(n) Premises maintained free of unnecessary items and litter out Clutter and old equipment is located in the kitchen area, preparation area, and near restrooms. There are old tires and trash near dumpster area. There is no visible paper or debris on the parking lot. Core (C) 3
Total Score Violation Score Inspection Score Inspection %
100 23 77 77
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 10 35 77
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 5 34 87