Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
05/03/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
Deli Walk-in Cooler 34F
Deli Walk-in Freezer -9F
Meat Display Cooler 30F
Cheese Display Cooler 28F
Produce Walk-in Cooler 36F
Meat Walk-in Cooler 33F
Meat Walk-in Freezer -5F
Grocery Walk-in Freezer -1F
Ice Cream Walk-in Freezer -9F
Dairy Cooler 35F
Retail Coolers 31 to 39F
Retail Freezers -10 to -1F

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Deli 3 Compartment Sink 200 J-512
Deli Sanitizer Spray Bottle 200 J-512
Meat 3 Compartment Sink 200 J-512

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out Observed that the PIC inside the meat department could not speak to sanitizer testing processes. When asked about how long you are suppose to submerge your test strip, the PIC stated that it was for 3 seconds. Also, when asked the proper rate of sanitizer the PIC stated that it was between 0-100 ppm. Per manufacturing label, a rate of 200 to 400ppm is the ideal percentage that is sufficient to sanitize. Per test strip information, you must dip your sanitizer test strip for 10 seconds in order to get an accurate reading for effectively sanitizing dishes, equipment, and touch points. Priority Foundation (PF) 0
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(6)(a) Food contact surfaces shall be visually clean. out Observed cheese residue set up on blade. Priority Foundation (PF) 0
14 0080-04-09-.04(5)(a)16 Sanitizer concentration shall be accurately determined out Observed that PIC could not speak to sanitizer concentration during today's inspection. Priority Foundation (PF) 0
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) out Observed thermometer inside the retail produce cooler, in front of Produce walk-in not working accurately. The thermometer registered at 20F and the case was at 38F Priority Foundation (PF) 0
Total Score Violation Score Inspection Score Inspection %
100 10 90 90
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 0 45 100
Priority (P) 49 0 49 100
Priority Foundation (PF) 39 4 35 89