08 Adequate handwashing sinks properly supplied and accessible |
in |
|
|
|
0 |
08 0080-04-09-.06(3)(a)3 Handwashing sinks, properly supplied with drying devices |
out |
No paper towels or other single use drying devices were avaliable in the restroom. |
|
Priority Foundation (PF) |
0 |
32 Approved thawing methods |
in |
|
|
|
0 |
32 0080-04-09-.03(5)(a)3 Thawing shall be performed in a refrigerator (under 41F) or submerged in cold running water. |
out |
Observed chicken thawing in the 3 compartment sink at room temperature. Discussed that thawing must occur under refrigeration or under cool running water to keep thawing foods below 41 degrees. |
|
Core (C) |
0 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(3)(b)2 Probe thermometer shall be readily accessible to check food temperatures |
out |
No probe thermometer was available in the firm. The PIC states that one was purchased for the firm after the last inspection but it was unable to be found. |
|
Priority Foundation (PF) |
1 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
No test strips were available to check sanitizer concentration in the 3 compartment sink. Firm uses bleach as sanitizer and needs chlorine test strips. |
|
Priority Foundation (PF) |
2 |
50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. |
out |
The unisex restroom does no have a covered trash can. Because this restroom may be used by females it must have a covered trash can in it. |
|
Core (C) |
0 |
50 0080-04-09-.06(2)(b)4 Toilet room shall have a self-closing tight fitting door |
out |
The unisex restroom door is not self closing. |
|
Core (C) |
2 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
Excessive ice build up observed in kitchen freezer. PIC states that a technician has already been contacted to repair the freezer. |
|
Core (C) |
0 |