44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used |
in |
|
|
|
0 |
44,45 0080-04-09-.04(2)(b)6 Nonfood-contact surfaces shall be designed and constructed to allow easy cleaning and to facilitate maintenance |
out |
Observed duct tape used inside several chest freezers to hold top door together.
**Observed several retail freezers with ice build up causing areas not to be cleanable. |
|
Core (C) |
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
Observed no test strips available for Chlorine sanitizer. Firm had only "Fruit Wash" test strips. |
|
Priority Foundation (PF) |
0 |
46 Non-food contact surfaces clean |
in |
|
|
|
0 |
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. |
out |
Observed vegetable spray misters with black organic matter on them. |
|
Core (C) |
0 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 49 Sewage and waste water disposal |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(4)(c) Sewage and waste water properly disposed through public sewer or approved septic system; including condensate drainage |
out |
Observed major leaking from under "Sanitize Basin" on 3 Compartment sink not allowing waste water to drain properly. |
|
Priority (P) |
0 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 51 Garbage and refuse properly disposed; facilities maintained |
in |
|
|
|
0 |
51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. |
out |
Observed dumpster to not be on concrete pad to deter contamination of ground water from dumpster waste. |
|
Core (C) |
0 |