01 PIC present, Knowledgeable, Duties |
in |
|
|
|
0 |
01 0080-04-09-.02(1)(b) Demonstration of knowledge |
out |
Observed that PIC needed additional instruction on the firms hot/cold holding temperatures.
**Observed PIC stated that they are using Quaternary ammonia but they have been using 'Chlorine Test Strips' to check calibration of sanitizer. |
|
Priority Foundation (PF) |
0 |
14 Food contact surfaces; clean and sanitized |
in |
|
|
|
0 |
14 0080-04-09-.04(5)(a)16 Sanitizer concentration shall be accurately determined |
out |
When asking PIC about sanitizer, I observed that PIC was using 'chlorine' test strips for there ammonia sanitizer and was not adequately able to determine the concentration of there sanitizer. |
|
Priority Foundation (PF) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
Observed firm using Chlorine test strips for Quaternary (Ammonia) used at firm. Firm is using Steramine Tablets. |
|
Priority Foundation (PF) |
2 |