Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
07/17/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
walk in cooler 37
prep cooler 40
reach in cooler retail 37

Food Temperatures


Description Temperature State Of Food
wings 134
pepperoni 140
cheese 157

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 comp sink 150 clorox

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out PIC without sanitizer sink set up or sanitizer on sight, no test strips and did not know how to measure sanitizer, had to go over proper cooking and hot holding temperatures. Priority Foundation (PF) 0
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)2 Handwashing sinks, properly supplied with soap out No soap in men's bathroom. Priority Foundation (PF) 0
08 0080-04-09-.06(3)(a)4 Handwashing aids and devices may not be provided for sinks not designated as hand sink; hand signs not provided out No hand wash signs in female or male bathroom. Core (C) 1
19,20 safe temperature holding in 0
19,20 20 Cold holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods out Prepackaged ranch dressing containers with information on package reading "must be refrigerated" sitting on shelf in deli at room temperature. Priority (P) 0
24,25 Chemical hazards in 0
24,25 25 Chemicals identified, stored, and used in 0
24,25 0080-04-09-.07(1) Chemicals shall have identifying Information out Spray bottles in deli area without identifying information. Priority Foundation (PF) 0
24,25 0080-04-09-.07(2)(a) Chemicals shall be stored separate from food, utensils, equipment, and single service items out Household chemicals stored above single service items in retail area. Priority Foundation (PF) 0
24,25 0080-04-09-.07(2)(b) Chemicals used according to law; pesticide shall be applied only by an certified applicator. out Ant and roach spray partially used on shelf in back storage area with other chemicals. Priority (P) 0
35,36 Pests & contamination in 0
35,36 36 Contamination prevented during food preparation, storage or display in 0
35,36 0080-04-09-.03(3)(e) Food shall be stored in a clean location, not exposed to contamination, at least 6 inches above the floor. Food shall not be stored in prohibited areas such as: locker/ch... out Boxes of chips stored on floor outside of women's restroom. Core (C) 0
37 Personal Cleanliness in 0
37 0080-04-09-.02(4)(c) Food employees shall wear hair restraints such as hats, hair coverings or nets, beard restraints, and clothing that covers body hair while working with exposed food. out Deli worker working with exposed food without hair restraint. Core (C) 0
38,39 wiping cloth & washing produce in 0
38,39 38 Wiping cloths properly used and stored in 0
38,39 0080-04-09-.03(3)(d)4 Wiping cloths shall be maintained dry or held in sanitizer; free of debris; wiping cloth storage containers are stored off the floor out Wiping clothes stored on 3-compartment sink and on handwash sink in deli area. Core (C) 0
42,43 Single service & gloves in 0
42,43 42 Single-service articles stored and used in 0
42,43 0080-04-09-.04(9)(c)1 Single-service articles protected from contamination out Case of cups on floor in back storage area. Core (C) 0
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out No test strips to measure sanitizer level. Priority Foundation (PF) 1
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out 3 compartment sink initially observed to not have cold water, PIC turned cold water on and the sink was observed to be leaking from cold water faucet. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 29 71 71
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 6 39 86
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 5 34 87