| 33 Thermometers provided and accurate |
in |
|
|
|
0 |
| 33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) |
out |
Observed probe thermometer in use cannot be calibrated (temperature range 120-200F). Digital probe thermometer available was not functional. |
Discussed hot and cold calibration methods for probe thermometer (32F in ice or 210-212F in boiling water). |
Priority Foundation (PF) |
0 |
| 33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable |
out |
Observed thermometers unavailable in display cooler, back storage cooler and retail cooler. All temperatures within parameters. |
|
Priority Foundation (PF) |
0 |
| 35,36 Pests & contamination |
in |
|
|
|
0 |
| 35,36 35 Insects, rodents, and animals not present |
in |
|
|
|
0 |
| 35,36 0080-04-09-.06(5)(k) Controlling Pests including evidence of pests and eliminating their presence. |
out |
Observed apparent rodent excrement under dry good shelving in back room. No live animal activity noted. |
|
Priority Foundation (PF) |
0 |