19,20 safe temperature holding |
in |
|
|
|
0 |
19,20 19 Hot holding temperature |
in |
|
|
|
0 |
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods |
out |
Observed chicken wings and wing bites in hot holding that when the temperature was taken with inspector's probe thermometer ranged from 121F-128F. This is below the minimum temperature of 135F for hot holding. |
PIC voluntarily discarded all out of temperature products. |
Priority (P) |
3 |
21,22 Date & Time for food safety |
in |
|
|
|
0 |
21,22 21 Date Marking and Disposition |
in |
|
|
|
0 |
21,22 0080-04-09-.03(5)(a)8 Date Marking; Discard food after 7 days at 41F |
out |
Observed multiple containers of sliced vegetables and meats for making pizza (sausage, pepperoni, jalapeno peppers, bacon, olives, onions) with a thaw date of 9/4 which should have been discarded by 9/10. |
PIC voluntarily discarded all product that was held beyond the 7-day limit. |
Priority (P) |
0 |
40,41 Utensils |
in |
|
|
|
0 |
40,41 40 In use utensils properly stored |
in |
|
|
|
0 |
40,41 0080-04-09-.03(3)(d)2 In use utensils for food preparation or dispensing shall be stored properly; handle above food, or in running water, and protected. |
out |
Observed the ice scoop stored directly on top of the ice machine not covered or protected from contamination. |
|
Core (C) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
Observed the only available test kits for quaternary ammonia expired on 9/1/24. Firm had test kits for bleach, but no unscented bleach was available. |
|
Priority Foundation (PF) |
1 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(2)(b)3 Air gap sufficient between water supply outlet and flood rim level |
out |
Observed the hose for the mop sink was stored directly in the mop sink below the flood rim. This does not create a sufficient air gap. |
PIC voluntarily moved hose above the flood rim. |
Priority (P) |
1 |