Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
09/05/2024 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Walk in freezer - kitchen 16
Pizza condiment cooler 39
deli cooler 37
main warmer 158
pizza warmer 118
2- 2 door coolers - kitchen 37, 39
novelty freezer -14
retail walk in cooler 35
dairy cooler 36

Food Temperatures


Description Temperature State Of Food
pizza 116
corn dogs 152
chicken 155
wings in pizza warmer 114, 102
wings in warmer 152

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 compartment ware washer 50/100 bleach

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(6)(b)1 Food contact cleaning frequency; 4 hours at ambient temperature out Observed the deli meat slicer has old food build up, needs to be broken down and cleaned and sanitized every 4 hours - discussed with the PIC. Priority (P) 0
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out Observed the pizza warmer @ 118 degrees, probed with the state issued probe thermometer wings @ 114, 102, pizza @ 116 degrees, all products were disposed of by PIC. Priority (P) 1
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out Facility is using bleach for sanitizer, the only test strips they have is for the quat sanitizer, the PIC ordered the correct test strips while I was at the Facility and should receive them on Friday. Priority Foundation (PF) 2
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Observed the kitchen vent hood has excessive grease build up. Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 11 89 89
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 1 44 97
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 1 38 97