08 Adequate handwashing sinks properly supplied and accessible |
in |
|
|
|
0 |
08 0080-04-09-.05(2)(e)1 Handwash sink shall only be used for washing hands; accessible at all times |
out |
Observed a hose hooked up to hand sink in kitchen at time of inspection. |
|
Priority Foundation (PF) |
0 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) |
out |
Food probe thermometer was checked via freeze point method and was reading 42 F degrees. |
|
Priority Foundation (PF) |
0 |
40,41 Utensils |
in |
|
|
|
0 |
40,41 41 Utensils, equipment, and linens; stored, dried, and handled |
in |
|
|
|
0 |
40,41 0080-04-09-.04(9)(d)1 Cleaned and sanitized utensils are handled, displayed, or dispensed to protect from contamination of food |
out |
Observed clean dishes stored on top of a lid of container that was sticky and greasy to touch at time of inspection. |
|
Core (C) |
0 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(2)(c)4 Plumbing system installed to prevent backflow of contaminant into the water supply system (hose bibb or vacuum breaker) |
out |
Observed a hose attached to hand sink and no vacuum breaker on the faucet before the hose is attached. |
Hose was disconnected at time of inpsection. |
Priority (P) |
0 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
Observed faucet knob on mop sink missing at time of inspection. |
|
Core (C) |
0 |