Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
10/10/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
Chest Freezer 0
One-Door Freezer -13
Fry Freezer -7
Retail Cooler 33

Food Temperatures


Description Temperature State Of Food
Catfish Steak 146
Fried Okra 141
Frozen Fries -2
Raw Fish 40

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Three-Compartment Sink Bleach

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
21,22 Date & Time for food safety in 0
21,22 21 Date Marking and Disposition in 0
21,22 0080-04-09-.03(5)(a)8 Date Marking; Discard food after 7 days at 41F out Sauces made and stored in the retail cooler were observed with dates longer than the seven-day holding time (date observed 9/17 and inspection done on 10/10/24). PIC removed sauce to dispose of and had dates present for spaghetti sauce and other sauces used for wings. Priority (P) 0
35,36 Pests & contamination in 0
35,36 35 Insects, rodents, and animals not present in 0
35,36 0080-04-09-.06(2)(b)3 Insect control devices shall not be installed over food preparation, clean equipment, utensil, single service items. out A fly catcher strip was observed installed over utensils (discussed installing in area where food and/or utensils and equipment is not at). Core (C) 0
42,43 Single service & gloves in 0
42,43 42 Single-service articles stored and used in 0
42,43 0080-04-09-.04(5)(b)3 Single-service articles shall not be reused. out A single-service ranch container was observed being used for storage to put sugar in (discussed leaving in original packaging or a container). Priority (P) 0
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(1)(a) Food contact equipment surfaces shall be safe, durable, corrosion-resistant, nonabsorbent, smooth, and easily cleanable out Cutting board was observed with grooves and stains on both sides of the board (PIC advised that they recently replaced a few months ago). Priority (P) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out There was excessive grease and debris on the floor around the fryers in the kitchen area. Core (C) 2
53 Ventilation, lighting, and designated areas used in 0
53 0080-04-09-.06(2)(b)2 Ventilation/hood system/filtration installed not to cause contamination out The vent hood had grease build up present. Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 14 86 86
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 3 42 93
Priority (P) 49 3 46 93
Priority Foundation (PF) 39 0 39 100