Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
11/12/2024 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Deli Meat Cooler 37
Deli Walk in Cooler 39
Deli/Bakery Walk in Freezer 4
Bakery Walk in Cooler 40
ODP Walk in Cooler 40
ODP Walk in Freezer 1
Produce Walk in Cooler 37
Meat Walk in Cooler 34
Meat Walk in Freezer -1
General Walk in Freezer -3
Ice Cream Walk in Freezer -4
Dairy Walk in Cooler 40

Food Temperatures


Description Temperature State Of Food
Rotisserie Chicken 39
Rotisserie Chicken 188

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
ware wash sink deli 300 Kay Quat 2
ware wash sink bakery Kay Quat 2
ware wash sink produce Kay Quat 2
ware wash sink meat dept. Kat Quat 2

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(6)(b)1 Food contact cleaning frequency; 4 hours at ambient temperature out 2 Slicers in the deli were observed to have food debris around blade from prior use. Slicers were not used on this date per deli employee. Slicers were broke down and cleaned during inspection. Priority (P) 0
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out The following TCS items were observed to be held below 135 F in the hot holding unit in the deli. Hot dog 101.5 F, Chicken egg roll 119.6 F, Breakfast Tater Keg 101.3 F, Chicken sandwich 108.3 F, Cheese Bomb Tater Keg 94.7 F, and Chicken slider 110.2 F. There were about 48 items in total. All temperatures were verified with TDA digital probe thermometer. All TCS food items in this case were discarded during inspection. Food Coach placed a work order on unit and employees were instructed not to use the hot hold unit until the issue was corrected. Priority (P) 0
35,36 Pests & contamination in 0
35,36 36 Contamination prevented during food preparation, storage or display in 0
35,36 0080-04-09-.03(3)(c)2 Storage or display of packaged food in contact with water or ice out General walk in freezer observed with heavy build-up frozen condensate located under overhead refrigeration unit on cases of food products at time of inspection. Manager stated that maintenance crew is currently working to correct the issue and all food cases with ice build-up were discarded during inspection. Core (C) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out Hood vents and hood in deli observed with grease build-up. Food Coach placed a work order for the cleaning of the hood and vents during inspection. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 14 86 86
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 2 43 95
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 0 39 100