Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
11/06/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
small counter top cooler 42
Chest freezers -5, -4, -10, -14, -12
walk in cooler 41
warmer 162
retail chest freezer -15
novelty freezer -26
dairy cooler 41

Food Temperatures


Description Temperature State Of Food
chicken tenders 155
smo. sausage 153
chicken on stick 155
boiled peanuts 145
corn dogs 155
chicken tenders 155

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 compartment ware washer 50/100 bleach

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.05(2)(e)1 Handwash sink shall only be used for washing hands; accessible at all times out Observed hand sink by the warmer is blocked with a box and food containers, ( PIC moved everything out of the sink during the inspection). Priority Foundation (PF) 0
08 0080-04-09-.06(3)(a)2 Handwashing sinks, properly supplied with soap out No soap at Hand sink by warmer, (PIC Changed the soap dispenser during the inspection) Priority Foundation (PF) 0
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) out Observed thermometer in the warmer is not working. Priority Foundation (PF) 0
33 0080-04-09-.04(3)(b)2 Probe thermometer shall be readily accessible to check food temperatures out No probe thermometer in kitchen to check proper food temperatures. Priority Foundation (PF) 0
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Observed 3 chest freezers have ice build up, needs to be defrosted, Novelty ice cream freezer has ice build up. Core (C) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out Observed grease build up on vent hood, walls, and floor in the kitchen area. Core (C) 2
Total Score Violation Score Inspection Score Inspection %
100 8 92 92
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 2 43 95
Priority (P) 49 0 49 100