Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
11/07/2024 High Risk Food Retail No Yes

Equipment Temperatures


Description Temperature
Upright Storage Freezer 13
Deli Prep Cooler 58
Chest Freezer #1 -13
Chest Freezer #2 -14
3 Door Storage Freezer 12
3 Door Storage Cooler 33
Walk in Cooler 41
Reach in Retail Milk Cooler 39

Food Temperatures


Description Temperature State Of Food
Fried Chicken 149
Chicken Tenders 172
Corn Dog 156
Chicken Sandwich 151
Sausage Patties (cooling 3.5 hours) 51
Hamburger Patty 201
Chili 38
Deli Sliced Ham 39
Deli Sliced Turkey 38
Raw Beef 37
Raw Chicken 36
Onion Rings 161

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 Bay Sink Not Set Up Steramine

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
21,22 Date & Time for food safety in 0
21,22 21 Date Marking and Disposition in 0
21,22 0080-04-09-.03(5)(a)7 Date Marking; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, ... out Observed a food container of Chili and a food container of Sausage patties stored in the 3-door storage cooler in the food service area to not be date marked. Date Marking requirements; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, dry fermented sausages, or salt-cured products. Priority (P) 0
24,25 Chemical hazards in 0
24,25 25 Chemicals identified, stored, and used in 0
24,25 0080-04-09-.07(1) Chemicals shall have identifying Information out Observed several filled chemical spray bottles stored under the 3-bay sink without identifying information. Priority Foundation (PF) 1
30,31 Food temp controls in 0
30,31 30 Proper cooling methods, adequate equipment for temperature control in 0
30,31 0080-04-09-.04(3)(a)1 Equipment for cooling, heating, cold holding, and hot holding food shall be sufficient in number and capacity to provide safe food temperatures. out Observed the sandwich station prep cooler to be 58*F, in need of repair. Prep Cooler was checked with a TDA infrared thermal gun. Priority Foundation (PF) 0
35,36 Pests & contamination in 0
35,36 36 Contamination prevented during food preparation, storage or display in 0
35,36 0080-04-09-.03(3)(e) Food shall be stored in a clean location, not exposed to contamination, at least 6 inches above the floor. Food shall not be stored in prohibited areas such as: locker/ch... out Observed heavy condensate dripping/leakage from the condenser fans onto packaged food in the Walk in Cooler. Core (C) 1
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(1)(a) Food contact equipment surfaces shall be safe, durable, corrosion-resistant, nonabsorbent, smooth, and easily cleanable out Observed the poly cutting board at the sandwich prep station to be heavily scored and discolored. Priority (P) 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out There was no test strips observed to be available at the facility. Priority Foundation (PF) 1
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Observed a build-up of food residue, debris, and condensate in the bottom of the 3-door storage cooler in the food service area. Core (C) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. out There was not a covered waste can observed to be available in the unisex employee restroom. Core (C) 0
50 0080-04-09-.06(5)(h) Toilet room cleaning frequency out The hand sink fixtures in the unisex customer and unisex employee restrooms were observed to have a heavy build-up of dirt and debris. Not properly cleaned. The toilet seat in the unisex restroom was observed to be broken and taped together, in need of repair. Core (C) 1
53 Ventilation, lighting, and designated areas used in 0
53 0080-04-09-.06(2)(b)1 Light bulbs shall be shielded or shatter-resistant over food preparation or storage. out Observed unshielded light bulb over food storage area of the walk-in cooler. Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 23 77 77
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 5 40 88
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 3 36 92