| 08 Adequate handwashing sinks properly supplied and accessible |
in |
|
|
|
0 |
| 08 0080-04-09-.05(2)(c)1 Handwashing sinks are installed according to the capacity of preparation areas |
out |
No hand sink in ice bagging area and facility also prep cup ice |
|
Priority Foundation (PF) |
0 |
| 19,20 safe temperature holding |
in |
|
|
|
0 |
| 19,20 20 Cold holding temperature |
in |
|
|
|
0 |
| 19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods |
out |
Retail cooler @ 50 degrees probed thermometer Lunchables @ 49 degrees all disposed |
|
Priority (P) |
0 |
| 33 Thermometers provided and accurate |
in |
|
|
|
0 |
| 33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable |
out |
No working thermometers in retail case |
|
Priority Foundation (PF) |
0 |
| 34 Food Properly labeled |
in |
|
|
|
0 |
| 34 0080-04-09-.03(6)(b) Food Label (common name, ingredient list, allergens, quantity, name & address of manufacturer), bulk food card/sign/placard; exempt for bulk unpackaged foods portioned to co... |
out |
Bagged ice not properly labeled with facility name and address |
|
Priority Foundation (PF) |
0 |
| 46 Non-food contact surfaces clean |
in |
|
|
|
0 |
| 46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. |
out |
Chest retail freezer and novelty cases need defrosting ice build up |
|
Core (C) |
0 |
| 50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
| 50 0080-04-09-.06(2)(b)4 Toilet room shall have a self-closing tight fitting door |
out |
Rest room door not self closing
|
|
Core (C) |
3 |
| 51,52 Facilities |
in |
|
|
|
0 |
| 51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
| 51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary |
out |
Ware wash area excessive clutter and hand sink not working ..
Even if facility is not using area Must be Maintained and kept clean |
|
Core (C) |
0 |
| 51,52 0080-04-09-.06(5)(n) Premises maintained free of unnecessary items and litter |
out |
Excessive trash in WIC on floor This has been discussed many times |
|
Core (C) |
0 |
| 51,52 0080-04-09-.06(5)(m) Maintenance tools such as brooms, mops, vacuum cleaners need to be properly stored; mops stored to air dry. |
out |
Mops observed not drying stored in dirty water |
|
Core (C) |
0 |