Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
06/14/2023 High Risk Food Retail Yes No

Equipment Temperatures


Description Temperature
Deli/Bakery WIC 37
Bakery WIF -1
Produce WIC 38
Meat/Seafood WIC 40
Dairy WIC 37
Backstock WIF -18
Retail open air cooler - dairy 42
Retail open air cooler - produce 40
Deli display case 36
Online order cooler 33
Online order freezer 0

Food Temperatures


Description Temperature State Of Food
Deli ham chub 35
Deli turkey chub 34
Deli corned beef chub 35

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Deli spray bottle 0 Sani Save
Deli/Bakery 3 compartment sink 200
Deli/Bakery Dishwasher 166.1

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
13 Food separated and protected in 0
13 0080-04-09-.03(3)(b)1(i)(I) Raw animal foods must be kept separate from ready to eat foods at all times out Observed raw smoked sausages stored above fully cooked sausages in retail meat cooler Priority (P) 0
13 0080-04-09-.03(3)(b)1(i)(II) Raw animal foods must be separated by species (unless intentionally combined) out Observed raw smoked turkey legs stored above raw smoked pork hocks in retail meat cooler. Observed raw ground beef stored above raw whole cuts of beef in retail meat cooler discount section. Priority (P) 0
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions out Observed a spray bottle actively being used to clean/sanitize a deli slicer with a concentration of 0ppm. Manufacturer recommends between 150 and 400 ppm. Priority (P) 0
14 0080-04-09-.04(5)(a)16 Sanitizer concentration shall be accurately determined out Observed PIC using test strip for sanitizer concentration incorrectly (submerged less than the 10 seconds per manufacturer's instruction) and was unsure of concentration requirements (stated between 100 and 200 ppm, recommendation is 150 to 400 ppm). Priority Foundation (PF) 0
47,48,49 Plumbing in 0
47,48,49 49 Sewage and waste water disposal in 0
47,48,49 0080-04-09-.05(4)(c) Sewage and waste water properly disposed through public sewer or approved septic system; including condensate drainage out Observed waste water leaking from handwash sink in seafood department ware washing area directly onto the floor while washing hands. In seafood department, there was an additional hand wash sink adjacent to ware washing and prep area (less than one foot away from leaking hand sink and not separated by a door or other potential obstacle). PIC voluntarily turned off water to leaking hand wash sink and placed a work order during inspection. Priority (P) 0
Total Score Violation Score Inspection Score Inspection %
100 13 87 87
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 0 45 100
Priority (P) 49 4 45 91
Priority Foundation (PF) 39 1 38 97