Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
01/14/2025 Medium Risk Food Retail Yes No

Equipment Temperatures


Description Temperature
Ice cream freezer #1 @ retail -3.4
Ice cream freezer #2 @ retail -6.8
Walk in cold holding unit 45.6
Open air Temperature Control for Safety Cold holding unit @ retail 40.1

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
N/A

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
19,20 safe temperature holding in 0
19,20 20 Cold holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods out Gallon and pint milks being stored in the walk in cold holding unit had an internal temperature of 48-50 degress F. Person in Charge voluntary removed from sale all the milk referenced in the violation. TDA placed an "x" on the top of the milk and facility segregated for discarding in the dumpster. Priority (P) 1
30,31 Food temp controls in 0
30,31 30 Proper cooling methods, adequate equipment for temperature control in 0
30,31 0080-04-09-.04(3)(a)1 Equipment for cooling, heating, cold holding, and hot holding food shall be sufficient in number and capacity to provide safe food temperatures. out Ambient temperature of the walk in cold holding unit were Temperature Control for Safety foods are being stored had a temperature of 45.5 to 46.7 degrees F. Priority Foundation (PF) 1
47,48,49 Plumbing in 0
47,48,49 47 Hot and cold water available in 0
47,48,49 0080-04-09-.05(1)(c) Hot and cold running water at sinks out The bathroom hot and cold water was observed to be turned off at the source. Person in charge (PIC) turned the hot and cold water on at the source during the routine inspection. PIC indicated that pipe had broken, and they are waiting on the repair plumber to fix the water. Priority Foundation (PF) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out The fan guards in the walk in cold holding unit had an excessive amount of dust on the condenser unit. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 15 85 85
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 1 44 97
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 2 37 94