| 19,20 safe temperature holding |
in |
|
|
|
0 |
| 19,20 20 Cold holding temperature |
in |
|
|
|
0 |
| 19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods |
out |
Observed various items (see temperature chart) requiring cold holding for safety, with an internal temperature greater than 41F when checked with Inspector's probe thermometer. |
PIC did voluntarily remove the items with an internal temperature greater than 43F and dispose of them in the dumpster. cutting open the packages and poured bleach over them to denature them. |
Priority (P) |
0 |
| 24,25 Chemical hazards |
in |
|
|
|
0 |
| 24,25 25 Chemicals identified, stored, and used |
in |
|
|
|
0 |
| 24,25 0080-04-09-.07(2)(a) Chemicals shall be stored separate from food, utensils, equipment, and single service items |
out |
Observed the following chemicals stored directly over single service items or food on the retail floor: Leather CPR and Family Guard disinfectant spray over cans of Maxwell House coffee, and Dunkin and Keurig K-Cup coffee; Yardley's soap and Arm & Hammer Body wash over plastic cups and foam cups. |
|
Priority Foundation (PF) |
1 |
| 47,48,49 Plumbing |
in |
|
|
|
0 |
| 47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
| 47,48,49 0080-04-09-.05(2)(c)3 At least one service sink or one curbed cleaning facility equipped with a floor drain shall be provided; Toilets shall not be used for the disposal of mop water and s... |
out |
Could not locate mop sink, employees were unaware of its location. A customer who works part time said it is located under the water heater in the back room, this area is blocked by an excessive amount of stock. |
|
Core (C) |
0 |
| 51,52 Facilities |
in |
|
|
|
0 |
| 51,52 51 Garbage and refuse properly disposed; facilities maintained |
in |
|
|
|
0 |
| 51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. |
out |
Observed one half of the dumpster lid to open with trash present. |
PIC did voluntarily close the lid. |
Core (C) |
2 |
| 51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
| 51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
Observed facet in unisex employee restroom to not be bolted to sink, this allowed it fall forward into the basin.
*Observed heavy brown staining and missing ceiling tiles on the retail floor. |
|
Core (C) |
0 |
| 51,52 0080-04-09-.06(5)(m) Maintenance tools such as brooms, mops, vacuum cleaners need to be properly stored; mops stored to air dry. |
out |
Observed mop stored inside a bucket the employee unisex restroom. |
|
Core (C) |
0 |