| 33 Thermometers provided and accurate |
in |
|
|
|
0 |
| 33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) |
out |
Both thermometers located in the hot holding table were not working properly. Both thermometers showed 120 degrees and when the hot holding table was scanned with an infrared thermometer the infrared showed 183 degrees. Needs new hot holding thermometers. |
|
Priority Foundation (PF) |
0 |
| 42,43 Single service & gloves |
in |
|
|
|
0 |
| 42,43 42 Single-service articles stored and used |
in |
|
|
|
0 |
| 42,43 0080-04-09-.04(9)(c)1 Single-service articles protected from contamination |
out |
Several stacks of foam food trays were observed on the white plastic kitchen rack not inverted or otherwise protected from contamination. |
The cook inverted these stacks of trays during the inspection. |
Core (C) |
0 |
| 51,52 Facilities |
in |
|
|
|
0 |
| 51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
| 51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
The gasket on the walk in cooler door is badly torn. Advised PIC that it needs repair to help maintain walk in cooler temperatures. |
|