| 16,17,18 cooking, reheating, cooling |
in |
|
|
|
0 |
| 16,17,18 18 Cooling time and temperature |
in |
|
|
|
0 |
| 16,17,18 0080-04-09-.03(5)(a)4(i) Cooling must occur within 2 hours from 135F to 70F and within a total of 6 hours from 135F to 41F or less. |
out |
Observed Sausage patties stored in the 3-door storage cooler 2 hours and 37 minutes into the cooling process to be 98*F; product never reached the required 70*F within the 2-hour window. Product was checked internally with a TDA probe thermometer. |
Management voluntarily discarded product during inspection. |
Priority (P) |
0 |
| 21,22 Date & Time for food safety |
in |
|
|
|
0 |
| 21,22 21 Date Marking and Disposition |
in |
|
|
|
0 |
| 21,22 0080-04-09-.03(5)(a)7 Date Marking; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, ... |
out |
Observed a food container of Chili, two food containers of country Gravy, a ziplock bag of deli Ham, and a container of Sausage patties stored in the 3-door storage cooler in the food service area to not be date marked. Date Marking requirements; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, dry fermented sausages, or salt-cured products. |
Management voluntarily discarded referenced product during inspection. |
Priority (P) |
1 |
| 24,25 Chemical hazards |
in |
|
|
|
0 |
| 24,25 25 Chemicals identified, stored, and used |
in |
|
|
|
0 |
| 24,25 0080-04-09-.07(1) Chemicals shall have identifying Information |
out |
Observed several filled chemical spray bottles stored under the primary hand sink in the kitchen area without identifying information.
|
|
Priority Foundation (PF) |
2 |
| 35,36 Pests & contamination |
in |
|
|
|
0 |
| 35,36 35 Insects, rodents, and animals not present |
in |
|
|
|
0 |
| 35,36 0080-04-09-.06(2)(b)5 Outer Openings - Protected |
out |
Observed an unprotected opening to the outside through the storage room wall where electrical lines go through wall. Seal opening to prevent possible pest entry. |
|
Core (C) |
0 |
| 35,36 0080-04-09-.06(5)(k) Controlling Pests including evidence of pests and eliminating their presence. |
out |
Observed rodent droppings along the left side wall in the food service kitchen area and in the cabinets at the self-service drink counter. |
|
Priority Foundation (PF) |
0 |
| 46 Non-food contact surfaces clean |
in |
|
|
|
0 |
| 46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. |
out |
Observed a build-up of food residue, debris, rust and condensate in the bottom of the 3-door storage cooler in the food service area. Observed heavy ice build-up in the upright storage freezer in the food service kitchen area; needs to be defrosted.
|
|
Core (C) |
1 |
| 47,48,49 Plumbing |
in |
|
|
|
0 |
| 47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
| 47,48,49 0080-04-09-.05(2)(c)4 Plumbing system installed to prevent backflow of contaminant into the water supply system (hose bibb or vacuum breaker) |
out |
Observed an open-ended hose in the mop sink, requires a hose bibb or vacuum breaker to prevent backflow of contaminant into the water supply system. |
|
Priority (P) |
0 |
| 50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
| 50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. |
out |
There was not a covered waste can observed to be available in the unisex employee restroom.
|
|
Core (C) |
1 |
| 50 0080-04-09-.06(5)(h) Toilet room cleaning frequency |
out |
The toilet seat in the unisex customer restroom was observed to be broken and taped together, in need of repair. |
|
Core (C) |
2 |
| 51,52 Facilities |
in |
|
|
|
0 |
| 51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
| 51,52 0080-04-09-.06(5)(a) Maintained in good repair |
in |
Observed numerous water damaged ceiling tiles throughout the facility; in need of repair or replaced. |
|
Core (C) |
0 |
| 53 Ventilation, lighting, and designated areas used |
in |
|
|
|
0 |
| 53 0080-04-09-.06(2)(b)1 Light bulbs shall be shielded or shatter-resistant over food preparation or storage. |
out |
Observed unshielded light bulb in the walk-in cooler where food is stored. |
|
Core (C) |