Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
04/29/2025 Low Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Reach in Freezers (2) -6, -13
Walk in Cooler 46

Food Temperatures


Description Temperature State Of Food
Half Gallon 2% Milk 49
Gallon 2% Milk 49
Orange Juice 49

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)4 Handwashing aids and devices may not be provided for sinks not designated as hand sink; hand signs not provided out No hand washing signs were observed in the men's restroom and in the women's restroom. Core (C) 1
19,20 safe temperature holding not applicable 0
19,20 20 Cold holding temperature not applicable 0
19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods out The walk in cooler was scanned with and infrared thermometer wat 46 degrees. Foods inside this cooler were probed with a state issued and calibrated thermometer. Two half gallons of 2% milk, one gallon of 2% milk, and a half gallon of orange juice were all measured at 49 degrees. The PIC voluntarily removed these items from display to crates in the walk in cooler. The PIC is putting in a service ticket to have the walk in cooler repaired. Priority (P) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. out The women's restroom did not have a covered trash can. Core (C) 1
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out Excessive paper and litter was observed on the floor of the walk in cooler Core (C) 3
51,52 0080-04-09-.06(5)(m) Maintenance tools such as brooms, mops, vacuum cleaners need to be properly stored; mops stored to air dry. out A damp mop was observed stored in a mop bucket next to the mop sink. Discussed with PIC training employees on storing cleaning tools properly. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 12 88 88
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 4 41 91
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 0 39 100