| 33 Thermometers provided and accurate |
in |
|
|
|
0 |
| 33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable |
out |
Observed damaged thermometer inside of the Walk-in Grocery freezer. Freezer thermometer registered at 20F and the freezer was -13F. I also observed a damaged bakery thermometer inside of the Walk-in cooler. Cooler registered at 36F and the thermometer stated it was 50F. |
|
Priority Foundation (PF) |
0 |
| 37 Personal Cleanliness |
in |
|
|
|
0 |
| 37 0080-04-09-.02(4)(c) Food employees shall wear hair restraints such as hats, hair coverings or nets, beard restraints, and clothing that covers body hair while working with exposed food. |
out |
Observed meat employee actively engaged in food preparation to be missing the proper beard net. |
|
Core (C) |
0 |
| 50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
| 50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. |
out |
Observed new female/unisex bathrooms missing the proper covered receptacle. |
|
Core (C) |
0 |
| 51,52 Facilities |
in |
|
|
|
0 |
| 51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
| 51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
Observed a drip from the Dairy Walk-in cooler condenser. The condenser was hit during operation and is being repaired. I also observed Chicken cooler drain to no be draining properly. The drain is puddling up because drain line was not cut low enough to properly drain when in use. |
|
Core (C) |
0 |