Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
09/11/2025 High Risk Food Retail Yes No

Equipment Temperatures


Description Temperature
Kitchen Prep Table 37F
Kitchen Prep Table 2 38F
Kitchen Display Cooler 37F
3 Door Kitchen Prep Freezer 10F
Walk-in Cooler 37F
Pie Case 39F
Steam Table 200F
Salad Cold Case 38F

Food Temperatures


Description Temperature State Of Food
Peeled Oranges 41F
Fresh Strawberries 40F
Blue Berries 42F
Peeled Lemons 41F
Beans 149F
Beef Strips 162F
Fried Rice 154F
Macaroni Salad 39F
Potato Salad 41F
Dressed Eggs 40F
Ceviche with raw fish 39F
Fried Chicken Tenders x 35 108 to 121F
Fried Tilapia 172F

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Sanitizer Bucket 350 Quaternary Ammonia

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out Observed tray of Fried chicken tenders with an internal temperature below 135F. Using my probe thermometer, the average temperature was between 108 to 121F. Priority (P) 0
24,25 Chemical hazards in 0
24,25 25 Chemicals identified, stored, and used in 0
24,25 0080-04-09-.07(1) Chemicals shall have identifying Information out Observed several chemical bottles up front, at the registers and also inside the kitchen missing the proper labeling of its contents. All spray bottles had clearish liquid as its contents. Priority Foundation (PF) 0
40,41 Utensils in 0
40,41 40 In use utensils properly stored in 0
40,41 0080-04-09-.03(3)(d)2 In use utensils for food preparation or dispensing shall be stored properly; handle above food, or in running water, and protected. out Observed ice scoop sitting directly on ice inside of the ice machine. Please ensure all ice scoops are not under a source of contamination. Core (C) 0
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out Observed firm using Quaternary Ammonia without the proper test strips. The firm only had Chlorine test strips. Priority Foundation (PF) 0
47,48,49 Plumbing in 0
47,48,49 48 Plumbing installed; backflow devices in 0
47,48,49 0080-04-09-.05(2)(b)3 Air gap sufficient between water supply outlet and flood rim level out Observed firm has 'capped' their floor drain and does not have the proper 3 inch air gap needed to ensure wastewater does not draw back up into your hand sinks piping. Priority (P) 0
Total Score Violation Score Inspection Score Inspection %
100 18 82 82
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 1 44 97
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 2 37 94