Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
01/07/2026 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
Kitchen Prep Cooler 37F
Kichen Creamer Cooler 35F
Kitchen Prep Cooler 2 37F
2 Door Cooler 37F
Prep Drawer 39F

Food Temperatures


Description Temperature State Of Food
Sausage Patty 39F
Eggs x 2 36 to 38F

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Sanitizer Bucket 0 Quaternary Ammonia
Sanitizer Bucket 2 200 Quaternary Ammonia 64F

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out Observed when asking PIC how long that they dip their test strips that I was told once the test strip turns different colors. Per manufacturer's instructions, test strips must be dipped for 10 seconds to get an accurate reading. Priority Foundation (PF) 0
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions out Observed bucket of sanitizer to register 00ppm using my test strips. PIC stated that bucket is full of sanitizer. Bucket was remade and sanitizer tested adequately. Priority (P) 0
42,43 Single service & gloves in 0
42,43 42 Single-service articles stored and used in 0
42,43 0080-04-09-.04(9)(c)1 Single-service articles protected from contamination out Observed several boxes of single serve cups sitting directly on the ground and not protected from contamination. Core (C) 0
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out Observed firm is using 2 different types of sanitizer: Chlorine and Quaternary Ammonia. The chlorine test strips were out of date, dated June 2025. Priority Foundation (PF) 0
47,48,49 Plumbing in 0
47,48,49 49 Sewage and waste water disposal in 0
47,48,49 0080-04-09-.05(4)(c) Sewage and waste water properly disposed through public sewer or approved septic system; including condensate drainage out Observed major leaking underneath the firm's ice chest stored underneath the counter, at the front of the store. The drainage line is leaking and dumping wastewater onto the floor. The firm is not able to contain leak. Priority (P) 1
53 Ventilation, lighting, and designated areas used in 0
53 0080-04-09-.06(4)(c) Designated area for personal items shall be located so that food and equipment are protected from contamination; personal belongings properly stored out Observed several employee beverages sitting around inside the firm's food preparation areas. Please ensure that your employees have a designated area for their personal items. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 18 82 82
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 2 43 95
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 2 37 94