Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
01/14/2026 High Risk Food Retail No Yes

Equipment Temperatures


Description Temperature
Bakery Cake Display Cooler x not in use
Deli Walk-in Cooler 37F
Bakery/Deli Walk-in Freezer 28F (freezer in use)
Produce Walk-in Cooler 38F
Meat Walk-in Cooler 37F
Meat/Grocery Walk-in Freezer -5F
Deli Display Cooler 38F
Dairy Walk-in Cooler 31F
Retail Coolers 36 to 39F
Retail Freezers -10 to 3F
Retail Chest Freezers -1 to 9F
To Go Coolers 38F
To Go Freezers -2F

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 Compartment Sink 300 Quaternary Ammonia 83F
Sanitizer Spray Bottle 200 Quaternary Ammonia 63F
3 Compartment Sink Meat 300 Quaternary Ammonia 79F
3 Compartment Sink Produce 200 Quaternary Ammonia 67F

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out Observed that PIC was unsure of how long to dip test strips to get an accurate reading of sanitizer. I walked PIC through proper sanitizer testing and rate. Priority Foundation (PF) 0
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(6)(a) Food contact surfaces shall be visually clean. out Observed both deli slicers were stored clean with encrusted cheese and food residue set up on the back of blades. I also observed several bakery tips that were stored clean with encrusted old icing inside of them. Inside the Meat department, I noted several cutting knives that were stored clean with encrusted food residue still on them. PIC stated that they no longer use these knives. I advised PIC to remove any equipment or utensils that they aren't using to ensure all equipment is getting cleaned and used daily. Priority Foundation (PF) 0
14 0080-04-09-.04(6)(b)1 Food contact cleaning frequency; 4 hours at ambient temperature out Observed no consistent Slicer cleaning log. Last date of cleaning was logged at 8/2025 and firm has used their slicers since this last cleaning. Priority (P) 0
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) out Observed both Dairy cooler thermometers were damaged and not working correctly during today's inspection. One thermometer registered at -20F when the interior registered at 31F using my thermal thermometer. Priority Foundation (PF) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out Observed the deli 3 compartment sink wash basin is leaking from drain piping when in use. Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 12 88 88
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 1 44 97
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 3 36 92