Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
08/14/2023 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Prep cooler 39
upright freezer -8
walk in freezer 5
walk in cooler 34

Food Temperatures


Description Temperature State Of Food
Chicken tenders 145
mashed potatoes 140
mac and cheese 138
fried chicken thigh 150
hamburger crumbles 40
sausage crumbles 40

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
3 bay sink

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
14 Food contact surfaces; clean and sanitized in 0
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions out No sanitizer available during inspection. Priority (P) 0
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out Fried chicken Breast and wings at hot bar observed to be 114 F to 129 F verified with TDA digital probe thermometer. Manager discarded product during inspection. Priority (P) 0
19,20 20 Cold holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(II) Cold holding at 41F or less for Time/temperature control for safety foods out Items in sandwich case observed to be held above 41 F. The following items were checked with TDA digital probe thermometer. Shredded beef burrito 67 F, Sausage, egg, and cheese biscuit 66 F, Big Az cheeseburger 65 F, and Steak and Jalapeno burrito 67 F. All items that were required to be held at or below 41 F were pulled by Manager and discarded during inspection. Manager states that this case will not be used until it has been properly fixed. Priority (P) 0
21,22 Date & Time for food safety in 0
21,22 21 Date Marking and Disposition in 0
21,22 0080-04-09-.03(5)(a)7 Date Marking; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, ... out Date marking system not in place on the following items at time of inspection. Creamer in creamer dispensing unit, sausage crumbles, hamburger crumbles, sliced onion, & sliced tomato. Deli employee and manager properly dated items during inspection. Priority (P) 1
21,22 0080-04-09-.03(5)(a)8 Date Marking; Discard food after 7 days at 41F out Tub of opened hot dogs observed to have a opening date of 7/25. Deli employee discarded item during inspection. Priority (P) 1
35,36 Pests & contamination in 0
35,36 35 Insects, rodents, and animals not present in 0
35,36 0080-04-09-.06(2)(b)5 Outer Openings - Protected out Front doors observed with a gap in between each set. Core (C) 0
35,36 0080-04-09-.06(5)(k) Controlling Pests including evidence of pests and eliminating their presence. out Rodent droppings observed on shelf near ice machine and gnawed coffee creamer units were present behind walk in freezer in back deli room at time of inspection. Priority Foundation (PF) 1
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(1)(a) Food contact equipment surfaces shall be safe, durable, corrosion-resistant, nonabsorbent, smooth, and easily cleanable out Food container observed to be stored on disposable towels on rack near 3 bay sink. Cardboard matting present on bottom self of prep table in kitchen. Deli employee removed towels and matting during inspection. Priority (P) 0
47,48,49 Plumbing in 0
47,48,49 48 Plumbing installed; backflow devices in 0
47,48,49 0080-04-09-.05(2)(b)1 Plumbing system designed, constructed, and installed according to LAW out Open ended drainpipe from hot water heater observed to be mounted above sanitizer bay of 3 bay sink. Core (C) 0
47,48,49 0080-04-09-.05(2)(c)4 Plumbing system installed to prevent backflow of contaminant into the water supply system (hose bibb or vacuum breaker) out Open ended hose attached to faucet of mop sink near ice machine without a backflow prevention devise hose bibb. Priority (P) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(2)(a) Floors, walls and ceilings - Designed, constructed, and installed smooth and easily cleanable out Multiple ceiling tiles were observed to have water damaged and a tile is missing in deli back room due to ceiling leaking. Core (C) 1
51,52 0080-04-09-.06(5)(a) Maintained in good repair out 2 gaskets on piping of 3 bay sink observed to be in need of repair. Paint on shelving above 3 bay sink is worn and in need of repair. Drain barrel in corner of deli from drink station observed to have old stagnate water present and needs to be drained and cleaned. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 25 75 75
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 4 41 91
Priority (P) 49 7 42 85
Priority Foundation (PF) 39 1 38 97