Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
11/28/2023 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Meat Walk-in Cooler 34
Meat Cutting Room 50
Produce Walk-in Cooler 37
Dairy Walk-in Cooler 39
Retail Meats Case 32/36/35
Retail Raw Meats Case 33/36/33
Retail Dairy Coolers 34/33
Retail Juice/Egg Case 34/36/35
Retail Produce Case 36/38/37
Retail Salad Coolers 32/36

Food Temperatures


Description Temperature State Of Food

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Meat 3 Bay Sink ClickSan
Produce 3 Bay Sink ClickSan

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
13 Food separated and protected in 0
13 0080-04-09-.03(3)(b)1(i)(I) Raw animal foods must be kept separate from ready to eat foods at all times out Observed raw pork products stored over ready-to-eat smoked hams in retail meats case. Priority (P) 0
34 Food Properly labeled in 0
34 0080-04-09-.03(6)(b) Food Label (common name, ingredient list, allergens, quantity, name & address of manufacturer), bulk food card/sign/placard; exempt for bulk unpackaged foods portioned to co... out Observed bottles of juice (not labeled for individual sale) for sale in retail area. Discussed keeping manufacturing, ingredient/allergen label from packaging with items. Priority Foundation (PF) 0
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(2)(b)6 Nonfood-contact surfaces shall be designed and constructed to allow easy cleaning and to facilitate maintenance out Observed rust on ceiling in meat walk-in cooler and dust build-up in crevice in ceiling in produce walk-in cooler. Discussed cleaning and sealing areas to prevent debris build-up and product contamination risk. Core (C) 0
47,48,49 Plumbing in 0
47,48,49 48 Plumbing installed; backflow devices in 0
47,48,49 0080-04-09-.05(2)(b)1 Plumbing system designed, constructed, and installed according to LAW out Observed leak from faucet and handle on left side of meat warewashing sink; also noted drip leak from drain pipe on same sink. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 12 88 88
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 2 43 95
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 1 38 97