08 Adequate handwashing sinks properly supplied and accessible |
in |
|
|
|
0 |
08 0080-04-09-.06(3)(a)4 Handwashing aids and devices may not be provided for sinks not designated as hand sink; hand signs not provided |
out |
There was no hand sign at the restroom hand sink. |
|
Core (C) |
0 |
14 Food contact surfaces; clean and sanitized |
in |
|
|
|
0 |
14 0080-04-09-.04(6)(b)1 Food contact cleaning frequency; 4 hours at ambient temperature |
out |
The deli slicer was observed with old food debris on it. |
|
Priority (P) |
0 |
40,41 Utensils |
in |
|
|
|
0 |
40,41 41 Utensils, equipment, and linens; stored, dried, and handled |
in |
|
|
|
0 |
40,41 0080-04-09-.04(9)(d)1 Cleaned and sanitized utensils are handled, displayed, or dispensed to protect from contamination of food |
out |
Food tongs were observed sitting on the prep table cooler, not covered/protected from contamination. |
|
Core (C) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
Chemical test strips were not available. |
|
Priority Foundation (PF) |
0 |
46 Non-food contact surfaces clean |
in |
|
|
|
0 |
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. |
out |
The vent guards and ceiling in the walk-in cooler had extreme dust build up and residue on it. |
|
Core (C) |
1 |
50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. |
out |
There was no covered receptacle in the restroom. |
|
Core (C) |
1 |
50 0080-04-09-.06(5)(h) Toilet room cleaning frequency |
out |
The employee restroom was unclean. The floor in the public restroom was unclean. |
|
Core (C) |
1 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 51 Garbage and refuse properly disposed; facilities maintained |
in |
|
|
|
0 |
51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. |
out |
The dumpster lid was open; making it accessible to pests. |
|
Core (C) |
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary |
out |
General cleaning is needed throughout the firm. |
|
Core (C) |
1 |
51,52 0080-04-09-.06(5)(n) Premises maintained free of unnecessary items and litter |
out |
There was old equipment and boxes throughout the firm causing extreme clutter. There was trash on the parking lot. |
|
Core (C) |
1 |
53 Ventilation, lighting, and designated areas used |
in |
|
|
|
0 |
53 0080-04-09-.06(4)(c) Designated area for personal items shall be located so that food and equipment are protected from contamination; personal belongings properly stored |
out |
Personal food items were stored with items that are being sold. |
|
Core (C) |
0 |