14 Food contact surfaces; clean and sanitized |
in |
|
|
|
0 |
14 0080-04-09-.04(6)(b)1 Food contact cleaning frequency; 4 hours at ambient temperature |
out |
Ice chute on fountain machine observed to have black organic matter present. |
|
Priority (P) |
0 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) |
out |
Thermometer in walk in cooler observed to be reading 26 F and face plate is cracked. Walk in cooler is running at 39 F verified with TDA thermal gun. |
|
Priority Foundation (PF) |
0 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(2)(c)4 Plumbing system installed to prevent backflow of contaminant into the water supply system (hose bibb or vacuum breaker) |
out |
Mop sink observed to have an open-ended hose attached to faucet and lying in bottom of basin without a backflow prevention device. |
|
Priority (P) |
0 |
50 Toilet facilities; constructed, supplied, cleaned |
in |
|
|
|
0 |
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. |
out |
Women's restroom did not have a covered trash can for feminine hygiene products at time of inspection. |
|
Core (C) |
0 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 51 Garbage and refuse properly disposed; facilities maintained |
in |
|
|
|
0 |
51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. |
out |
Outside dumpster observed with a broken lid. |
|
Core (C) |
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(5)(a) Maintained in good repair |
out |
Line under fountain drink counter observed to be dripping liquid at time of inspection. |
|
Core (C) |
0 |