08 Adequate handwashing sinks properly supplied and accessible |
in |
|
|
|
0 |
08 0080-04-09-.05(2)(e)1 Handwash sink shall only be used for washing hands; accessible at all times |
out |
The handwashing sink is obstructed by a pizza maker machine, making it inaccessible for employees to properly wash their hands. |
|
Priority Foundation (PF) |
1 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable |
out |
There was no thermometer in the hot holding warmer. |
|
Priority Foundation (PF) |
0 |
35,36 Pests & contamination |
in |
|
|
|
0 |
35,36 35 Insects, rodents, and animals not present |
in |
|
|
|
0 |
35,36 0080-04-09-.06(5)(k) Controlling Pests including evidence of pests and eliminating their presence. |
out |
Flies were observed in the kitchen area. |
|
Priority Foundation (PF) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used |
in |
|
|
|
0 |
44,45 0080-04-09-.04(2)(b) All multiuse equipment must be cleanable including food contact, CIP, lacking "V" threads, oil filtering, can openers, nonfood contact, shelving, and ventilation hoods |
out |
The vent hood had grease buildup. |
|
Priority Foundation (PF) |
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
There were no chemical test strips available. |
|
Priority Foundation (PF) |
0 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(2)(a) Floors, walls and ceilings - Designed, constructed, and installed smooth and easily cleanable |
out |
The ceiling in the walk-in cooler (dripping water on box of chicken but PIC moved the chicken), and near the three-compartment sink had water dripping from it (PIC stated that it is condensation from the cooling unit). |
|
Core (C) |
0 |
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary |
out |
The food preparation area needs general cleaning (cleaning of food contact surfaces). |
|
Core (C) |