Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
10/10/2023 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Retail freezer -8
sandwich cooler 38
walk in cooler 35
upright freezer -4

Food Temperatures


Description Temperature State Of Food
tornado 136

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
ware wash sink Steramine

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.05(2)(e)1 Handwash sink shall only be used for washing hands; accessible at all times out Hand sink at ware wash sink observed to have soiled food utensils inside wash bay. Items were taken out of hand sink during inspection. Priority Foundation (PF) 0
08 0080-04-09-.06(3)(a)4 Handwashing aids and devices may not be provided for sinks not designated as hand sink; hand signs not provided out No hand wash signs observed in restrooms. Core (C) 0
21,22 Date & Time for food safety in 0
21,22 21 Date Marking and Disposition in 0
21,22 0080-04-09-.03(5)(a)7 Date Marking; 6 days beyond the day of creation; exceptions are commercially made deli salads, hard cheeses, semi-soft cheeses, cultured dairy products, preserved fish, ... out Creamer in holding unit observed without being date marked. Manager discarded creamer in unit. Creamer was replenished with unopened bags and date marked during inspection. Priority (P) 3
24,25 Chemical hazards in 0
24,25 25 Chemicals identified, stored, and used in 0
24,25 0080-04-09-.07(2)(a) Chemicals shall be stored separate from food, utensils, equipment, and single service items out Bottle of multi-surface cleaner observed on drain board of ware wash sink on the sanitizer side. Item was relocated to an appropriate location by manager during the inspection. Priority Foundation (PF) 4
33 Thermometers provided and accurate in 0
33 0080-04-09-.04(2)(d)9 Temperature Measuring Devices shall be located in hot and cold holding units; easily readable out No thermometer was observed in creamer dispensing unit. Manager placed a thermometer in creamer unit during inspection. Priority Foundation (PF) 0
38,39 wiping cloth & washing produce in 0
38,39 38 Wiping cloths properly used and stored in 0
38,39 0080-04-09-.03(3)(d)4 Wiping cloths shall be maintained dry or held in sanitizer; free of debris; wiping cloth storage containers are stored off the floor out Soiled wiping cloth observed not to be held in a sanitizing solution beside hand wash sink on counter top. Core (C) 0
40,41 Utensils in 0
40,41 41 Utensils, equipment, and linens; stored, dried, and handled in 0
40,41 0080-04-09-.04(9)(d)1 Cleaned and sanitized utensils are handled, displayed, or dispensed to protect from contamination of food out Food containers observed to be stored in and on ware wash sink and drain board of sanitizer side of sink. Core (C) 0
44,45 Utensils and equipment in 0
44,45 45 Warewashing facilities installed, maintained, and used; test strips in 0
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. out No quaternary test strip was available at time of inspection. Priority Foundation (PF) 0
44,45 0080-04-09-.04(5)(a)4 Warewashing equipment shall be cleaned before use, to prevent recontamination, and at least every 24 hours if used. out Ware wash sink observed to have paper towels, old food debris and damaged products on drain boards and inside basin. Core (C) 4
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Old splatter observed on underside of fountain drink dispensing units. Core (C) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.05(5)(a)7 A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. out No covered receptacle for feminine hygiene products observed in women's restrooms. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 22 78 78
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 6 39 86
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 4 35 89