14 Food contact surfaces; clean and sanitized |
in |
|
|
|
0 |
14 0080-04-09-.04(6)(a) Food contact surfaces shall be visually clean. |
out |
White organic matter observed on top portion of F'Real Milkshake machine where mixing arm attaches to machine.
**Encrusted brown organic matter observed inside ice chutes on retail soda fountain machine. |
|
Priority Foundation (PF) |
2 |
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions |
out |
Sanitizer concentration observed not to reach the required concentration of 50ppm for chlorine sanitizer in dish machine. Sanitizer concentration observed to reach 0ppm with inspector test strip. |
|
Priority (P) |
2 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used |
in |
|
|
|
0 |
44,45 0080-04-09-.04(2)(b) All multiuse equipment must be cleanable including food contact, CIP, lacking "V" threads, oil filtering, can openers, nonfood contact, shelving, and ventilation hoods |
out |
Excessive ice build-up observed in novelty ice cream freezer and stand-up reach-in freezer making the surface no longer cleanable. |
|
Priority Foundation (PF) |
0 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 48 Plumbing installed; backflow devices |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(2)(b)3 Air gap sufficient between water supply outlet and flood rim level |
out |
Drain pipe from dish machine observed below the floor rim of the floor drain. Air gap not sufficient to prevent back siphonage/backflow. |
|
Priority (P) |
0 |
51,52 Facilities |
in |
|
|
|
0 |
51,52 51 Garbage and refuse properly disposed; facilities maintained |
in |
|
|
|
0 |
51,52 0080-04-09-.05(5)(a) Waste containers durable & cleanable; inaccessible to pests; drain plugs as required; outside dumpster on cleanable surface; outside dumpster properly constructed. |
out |
Excessive trash build-up observed on ground around outside dumpster. |
|
Core (C) |
0 |
51,52 52 Physical facilities installed, maintained, clean |
in |
|
|
|
0 |
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary |
out |
Excessive grease build-up observed on floor and wall under/behind fryer in kitchen area. |
|
Core (C) |
0 |