Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
01/31/2024 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
upright freezer -9
upright freezer -4
prep cooler 38
walk in cooler 34
sandwich cooler 33

Food Temperatures


Description Temperature State Of Food
cheese burger 136
steak, egg and cheese sandwich 133
country ham and cheese sandwich 137
sliced bologna 41
country ham 40

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
ware wash sink Steramine

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
01 PIC present, Knowledgeable, Duties in 0
01 0080-04-09-.02(1)(b) Demonstration of knowledge out Managers did not know the proper hot holding and cold holding temperatures pertaining to the foods in the deli. Priority Foundation (PF) 0
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)3 Handwashing sinks, properly supplied with drying devices out Hand sink in prep kitchen and hand sink in employee restroom were observed without a hand drying device. (paper towels) Employee supplied hand sinks with paper towels during inspection. Priority Foundation (PF) 0
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out The following food items were observed to be held below 135 F. All temperatures were taking with a TDA digital probe thermometer. Fried Bologna sandwich 112 F, Sausage biscuit 112 F, Tenderloin biscuit with egg and cheese 111 F, Sausage, egg, and cheese biscuit 110 F, chicken sandwich with cheese 130 F, Bosol pizza roll 112 F, and Corn Dog 110 F. Manager discarded all food items during inspection. Priority (P) 0
34 Food Properly labeled in 0
34 0080-04-09-.03(6)(b) Food Label (common name, ingredient list, allergens, quantity, name & address of manufacturer), bulk food card/sign/placard; exempt for bulk unpackaged foods portioned to co... out Store bagged ice observed not to have proper labeling stating Store name and address. Priority Foundation (PF) 1
35,36 Pests & contamination in 0
35,36 35 Insects, rodents, and animals not present in 0
35,36 0080-04-09-.06(5)(k) Controlling Pests including evidence of pests and eliminating their presence. out Rodent droppings observed on shelves under candy section and chip section in retail area. Priority Foundation (PF) 1
40,41 Utensils in 0
40,41 41 Utensils, equipment, and linens; stored, dried, and handled in 0
40,41 0080-04-09-.04(9)(d)1 Cleaned and sanitized utensils are handled, displayed, or dispensed to protect from contamination of food out Clean food utensils observed to be stored in a metal pan with old food debris present. Core (C) 0
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(1)(a) Food contact equipment surfaces shall be safe, durable, corrosion-resistant, nonabsorbent, smooth, and easily cleanable out Fry baskets observed to have loose or broken wires. Ice scoop is cracked. Priority (P) 1
44,45 0080-04-09-.04(2)(b)6 Nonfood-contact surfaces shall be designed and constructed to allow easy cleaning and to facilitate maintenance out Shelving in walk in cooler and splash guard at hand sink in kitchen prep area observed to have peeling contact paper. Core (C) 1
47,48,49 Plumbing in 0
47,48,49 48 Plumbing installed; backflow devices in 0
47,48,49 0080-04-09-.05(2)(c)4 Plumbing system installed to prevent backflow of contaminant into the water supply system (hose bibb or vacuum breaker) out Open ended hose observed to be lying in the bottom basin of the mop sink without a backflow prevention device. (Hose Bibb vacuum breaker) Hose was hung on a hook located above the sink during inspection. Priority (P) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out Wall and floor around the cook stations in kitchen observed to have grease build-up. Core (C) 2
Total Score Violation Score Inspection Score Inspection %
100 29 71 71
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 3 42 93
Priority (P) 49 3 46 93
Priority Foundation (PF) 39 4 35 89