14 Food contact surfaces; clean and sanitized |
in |
|
|
|
0 |
14 0080-04-09-.04(7)(c) Hot water and/or sufficient chemical sanitizer; default time of 30 seconds in contact with utensils; see manufacture's instructions |
out |
Observed sanitizer in 3 compartment sink with 0 PPM at time of inspection. |
PIC removed water and replaced with new sanitizer water at time of inspection. |
Priority (P) |
0 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(5)(b)1 Good Repair and Calibration (Thermometers shall be accurate to plus or minus 2F) |
out |
Observed 2 thermometers via ice point method and one reading 50 F and one reading 38 F, neither one was calibrated correctly at time of inspection. |
|
Priority Foundation (PF) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 45 Warewashing facilities installed, maintained, and used; test strips |
in |
|
|
|
0 |
44,45 0080-04-09-.04(3)(b)4 Test Kits to measure concentration of sanitizing solutions. |
out |
Facility is using a chlorine base sanitizer and no strips were available at time of inspection. |
|
Priority Foundation (PF) |
0 |