19,20 safe temperature holding |
in |
|
|
|
0 |
19,20 19 Hot holding temperature |
in |
|
|
|
0 |
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods |
out |
Numerous items in hot holding unit holding hamburgers, chicken sandwich's, sausage biscuits, etc observed not maintaining TCS food items at 135F or above with temperatures ranging between 121F-130F with inspector probe thermometer. |
PIC voluntarily discarded items not maintained at 135F or above. |
Priority (P) |
0 |
33 Thermometers provided and accurate |
in |
|
|
|
0 |
33 0080-04-09-.04(3)(b)2 Probe thermometer shall be readily accessible to check food temperatures |
out |
Firm observed not to have a probe thermometer available. PIC stated he does not think they have a probe thermometer. |
|
Priority Foundation (PF) |
0 |
35,36 Pests & contamination |
in |
|
|
|
0 |
35,36 35 Insects, rodents, and animals not present |
in |
|
|
|
0 |
35,36 0080-04-09-.06(2)(b)5 Outer Openings - Protected |
out |
Gap in front door observed large enough to allow for pest entry. Front door observed not to close properly leaving a large gap. |
|
Core (C) |
1 |
40,41 Utensils |
in |
|
|
|
0 |
40,41 40 In use utensils properly stored |
in |
|
|
|
0 |
40,41 0080-04-09-.03(3)(d)2 In use utensils for food preparation or dispensing shall be stored properly; handle above food, or in running water, and protected. |
out |
Ice scoop observed with handle stored in direct contact with ice in ice maker.
**Scoop observed with handles stored in direct contact with sugar in bulk sugar bin. |
|
Core (C) |
0 |
44,45 Utensils and equipment |
in |
|
|
|
0 |
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used |
in |
|
|
|
0 |
44,45 0080-04-09-.04(2)(b) All multiuse equipment must be cleanable including food contact, CIP, lacking "V" threads, oil filtering, can openers, nonfood contact, shelving, and ventilation hoods |
out |
Excessive ice build-up observed in outside ice chest freezer and novelty ice cream freezer making the surface no longer cleanable. |
|
Priority Foundation (PF) |
0 |
47,48,49 Plumbing |
in |
|
|
|
0 |
47,48,49 49 Sewage and waste water disposal |
in |
|
|
|
0 |
47,48,49 0080-04-09-.05(4)(c) Sewage and waste water properly disposed through public sewer or approved septic system; including condensate drainage |
out |
Liquid observed not to drain properly in three compartment sink. Left hand wash basin observed filled with liquid with the drain stop in place. When drain stop was removed water slowly drained from left hand basin and backed up into middle basin of three compartment sink. Liquid then stopped draining from both left hand and middle basins of three compartment sink. |
|
Priority (P) |