Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
03/28/2024 High Risk Food Retail Yes Yes

Equipment Temperatures


Description Temperature
Deli Cold Case 36
Deli Standup RIC 37
Deli Retarder 40
Deli Retail Cold Case 35
Produce Wall 39
Produce Walk in Cooler 40
Meat Walk in Cooler 33
Seafood Walk in Cooler 34
Meat/Seafood Cold Case 37
Dairy Walk in Cooler 35

Food Temperatures


Description Temperature State Of Food
Fried Chicken 198
Potato Salad 47
Ham Chub 38
Salmon Filet 33
Rotisserie Chicken 37
Cinnamon Apples 142
Chicken Tender 147
Scrambled Eggs 137

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Deli Spray Bottle 250 Chemstar
Deli 3-Compartment Sink 400 Chemstar
Bakery 3-Compartment Sink 350 Chemstar
Produce 3-Compartment Sink 200 Chemstar
Meat 3-Compartment Sink 250 Chemstar
Seafood 3-Compartment Sink 300 Chemstar

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
16,17,18 cooking, reheating, cooling in 0
16,17,18 18 Cooling time and temperature in 0
16,17,18 0080-04-09-.03(5)(a)4(ii) Cooling must occur within four hours to 41°F or less from ambient temperature out Observed a deli employee placing 'Godfather' sandwiches in the deli display cooler, immediately after preparation. Sandwiches were tempt at 47F with state calibrated thermometer Priority (P) 0
46 Non-food contact surfaces clean in 0
46 0080-04-09-.04(6)(a)1(iii) Non-food contact surfaces shall be kept free of an accumulation of dust, dirt, food residue, and other debris. out Observed dust build up on the deli ceiling vent and condenser fan guards in the bakery walk in freezer and the meat walk in cooler. ***observed pink organic build up on the seafood ice maker door frame. Core (C) 1
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out Observed a leak from the meat/seafood departments room washing hoses. The leak was causing water to pool in the seafood department floor. Core (C) 0
53 Ventilation, lighting, and designated areas used in 0
53 0080-04-09-.06(2)(b)2 Ventilation/hood system/filtration installed not to cause contamination out Observed grease drip around the rim of the deli fryer vent hoods. Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 9 91 91
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 3 42 93
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 0 39 100