Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
02/29/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
Dairy Walk-in Cooler 27
Meat/Deli Walk-in Cooler 40
Bakery Walk-in Cooler 30
Produce Walk-in Cooler 37
Pickup Walk-in Cooler 34
Meat Walk-in Cooler 39
Seafood Retail Case 33
Deli Case 28

Food Temperatures


Description Temperature State Of Food
Baked Beans 153
Ground Beef 29
Lettuce 37
Hot Dogs (Deli) 105, 120
Ham 27
Chicken 41
Milk 25
Chobani Yogurt 33
Eggs 35
Macaroni 136
Potato Wedges 137
Chicken Wings 178
Gravy 183
Tilapia -4
Tater Keg 182

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
Three-Compartment Sink (Bakery)
Three-Compartment Sink (Deli)
Three-Compartment Sink (Produce)
Three-Compartment Sink (Meat)

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
19,20 safe temperature holding in 0
19,20 19 Hot holding temperature in 0
19,20 0080-04-09-.03(5)(a)6(i)(I) Hot holding at 135F or above for Time/temperature control for safety foods out Hot dogs located in the deli department display hot holding unit were observed at a temperature below 135 degrees Fahrenheit (probed with the state calibrated thermometer at an internal temperature of 105F and another hot dog probed by the employee present at an internal temperature of 120F-Hot holding warmer was reading 170F Fahrenheit and the state issued surface thermometer was reading 172F-discussed with PIC and employee present that temperatures in hot holding warmers should maintain a temperature of 135F even in an open warmer cabinet/case). Priority (P) 0
35,36 Pests & contamination in 0
35,36 35 Insects, rodents, and animals not present in 0
35,36 0080-04-09-.06(2)(b)5 Outer Openings - Protected out Receiving doors had a gap at the bottom of them, making it an entryway for possible pests/rodents (PIC advised that she would put a work order in to replace the brush at the bottom). Core (C) 0
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out 1) The cooling unit in the walk-in cooler has excessive ice buildup due to the cooling unit. 2) The women's public restroom has a leak at one of the toilets. 3) Ice was observed forming on the cooling unit in the frozen foods walk-in freezer. Core (C) 0
51,52 0080-04-09-.06(5)(b) Physical facilities shall be cleaned as often as necessary out 1) Berries Walk-in Cooler- There was trash and debris underneath the racks. 2) Meat Walk-in Cooler-There was trash and debris underneath the racks. 3) Dairy-There was milk spillage in the walk-in cooler. 4) Vent guards in the walk-in cooler had dust build up on it. The PIC asked employees to clean the floors. Core (C) 1
Total Score Violation Score Inspection Score Inspection %
100 10 90 90
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 3 42 93
Priority (P) 49 1 48 97
Priority Foundation (PF) 39 0 39 100