Inspection

Food Safety Retail Inspection

Inspection details


Inspection Date Inspection Type In Person/Virtual Establishment Type Risk Type Permit posted Previous inspection available
02/21/2024 High Risk Food Retail No No

Equipment Temperatures


Description Temperature
deli cooler41 41
pizza prep not working
ice cream -9

Food Temperatures


Description Temperature State Of Food
deli ham 42
ice cream 18

Warewashing Information


Machine Name ppm Sanitizer Name Sanitizer Type Temperature
warewash bleach 50 clorox 65

Violations


Violation Status Observations Corrective Actions Violation Category Repeat
08 Adequate handwashing sinks properly supplied and accessible in 0
08 0080-04-09-.06(3)(a)3 Handwashing sinks, properly supplied with drying devices out using cloth towels at handsink in deli and one in restroom, must have a dryer, or paper towels. Priority Foundation (PF) 0
08 0080-04-09-.06(3)(a)4 Handwashing aids and devices may not be provided for sinks not designated as hand sink; hand signs not provided out no hand wash sign in restroom or at deli handsink Emailing a cop of handwash sign Core (C) 0
24,25 Chemical hazards in 0
24,25 25 Chemicals identified, stored, and used in 0
24,25 0080-04-09-.07(2)(b) Chemicals used according to law; pesticide shall be applied only by an certified applicator. out open bait at corner of retail shelf on glue trap, bait must be enclosed container Priority (P) 0
44,45 Utensils and equipment in 0
44,45 44 Food and Non-food contact surfaces, cleanable, designed, constructed, and used in 0
44,45 0080-04-09-.04(1)(a) Food contact equipment surfaces shall be safe, durable, corrosion-resistant, nonabsorbent, smooth, and easily cleanable out handle off of metal ice scoop, needs replacing Priority (P) 0
50 Toilet facilities; constructed, supplied, cleaned in 0
50 0080-04-09-.06(2)(b)4 Toilet room shall have a self-closing tight fitting door out no self closure Core (C) 1
51,52 Facilities in 0
51,52 52 Physical facilities installed, maintained, clean in 0
51,52 0080-04-09-.06(2)(a) Floors, walls and ceilings - Designed, constructed, and installed smooth and easily cleanable out ceiling damage in deli area Core (C) 0
51,52 0080-04-09-.06(5)(a) Maintained in good repair out hot water heater leaking Core (C) 0
Total Score Violation Score Inspection Score Inspection %
100 15 85 85
Violation Category Total Count Violation Count Inspection Count Inspection %
69 0 69 100
Core (C) 45 4 41 91
Priority (P) 49 2 47 95
Priority Foundation (PF) 39 1 38 97